Home
1
Products
2
AGM040 40W Medical desktop Power Adapter 3
Astek catch your demand on Power Supply Astek catch Your Demand on Power Supplies '
Home Products Medical Adapter AGM040 40W Medical desktop Power Adapter
127

AGM040 40W Medical desktop Power Adapter

*Input 90~264VAC *Output 5V~58V*DOE VI/CoC 5 *Protections: Overcurrent/ Overvoltage/Short Circuit
*Means of Patient Protection Design *Possess risk analysis report **Two years warranty *UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1) *EMC: IEC60601-1-2:2014 (ED 4.0), CE, FCC *Means of Protection: 2 X MOPP

131ac42018244616bf09fcc023ee3f4c.jpg

AGM040  40W Medical Desktop Adapter

*Universal AC Input Range

*DOE VI/CoC 5

*Protections: Overcurrent/ Overvoltage/Short Circuit

*Means of Patient Protection Design

*Possess risk analysis report

UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1)

* EMC: IEC60601-1-2:2014 (ED 4.0), CE, FCC
* Means of Protection: 2 X MOPP

*Warranty two Years

*Application: Medical power, Medical charger(CV mode), Power Supply for Healthcare

Input Voltage: 90~264VAC

Frequency: 50~60Hz

Input current: 1A max.   

Leakage Current: 0.1mA max. @240VAC /50Hz                          

Inrush current: 50A @115VAC; 90A @230VAC at 25°C cold start  

Part No       Rated O/P(current max.)        Ripple & Noise(mV p-p)

AGM040-S05-z      5-6V/5-4.17A/25W                150

AGM040-S75-z      6-8V/5-3.75A/30W                150

AGM040-S09-z      8-11V/4.5-3.27A/36W           150

AGM040-S12-z      11-13V/3.63-3.07A/40W       150

AGM040-S15-z      13-16V/3.07-2.5A/40W         200

AGM040-S18-z      16-21V/2.5-1.9A/40W           200

AGM040-S24-z      21-27V/1.9-1.48A/40W         200

AGM040-S27-z      27-33V/1.48-1.21A/40W       300

AGM040-S48-z      33-58V/1.21-0.68A/40W       300

 z: C6/C8/C14 inlet               Mechanical Attached: AGM040 desktop mechanical 

Load Regulation: +/-5% Max.

Line Regulation: +/-1% Max.  

Insulation resistance: 50Mohm min. from Input to output                    

Over Current Hiccup mode; auto-recovery, rate output current >110%

Over Voltage Protection: Protected by Zerner diode, Rated output voltage 110~140%

Short circuit Protection: auto recovery; Hiccup mode

Setup/Hold up/ Rise time: Typ.: 1000mS/10mS/50mS at full load

Efficiency: DOE VI

Derating: Derated from 100% at +40°C linearly to 50% at +70°C

Temperature Coefficient: All output +/-0.04% / °C max.

Withstand Voltage: 5656VDC from input to output

Operating Temperature: 0~40degree C

Storage Temperature: -40~85degree C

Storage Humidity: 5~95% RH

Transient Response: Max. Excursion of 4% better on all models. Recovering to 1% of final value within 500uS. after a 25% step load change

Safety: UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1)

EMC: IEC60601-1-2:2014 (ED 4.0), CE, FCC

Spec Attached: AGM040 desktop.docx

Medical Adapter 812949