Products
Astek catch your demand on Power Supply Astek catch Your Demand on Power Supplies '
Home Medical Adapter AGM050 50W Medical Desktop Adapter

AGM050 50W Medical Desktop Adapter

*Medical adapter *Input 90~264VAC *Output 3V~58V*High Efficiency and reliability*Protections: Overcurrent/Overvoltage/Over Temperature* UL,cUL60601, EN/IEC60601 with 3rd Edition, CE, FCC*Warranty 2years

AGM050  50W Medical Desktop Adapter

 *Universal AC Input Range

*High Efficiency and reliability

*Protections: Overcurrent/ Overvoltage/Over Temperature

* UL, cUL60601, EN/IEC60601 with 3rd Edition and CE, FCC approved.

*Warranty two Years

*Application: Medical power, Medical charger(CV mode), Power Supply for Health care

Input Voltage: 90~264VAC

Frequency: 50~60Hz

Input current: 1.5-0.8A max.   

Leakage Current: 0.3mA max. @240VAC /50Hz                          

Inrush current: 65A @115VAC; 90A @230VAC at 25°C cold start  

Part No          Rated O/P(current max.)        Ripple & Noise(mV p-p)

AGM050-S03-z      3-5V/7.5A/37.5W                    50

AGM050-S05-z      5-6V/7.5-6.25A/37.5W            50

AGM050-S75-z      6-8V/6.66-5A/40W                  75

AGM050-S09-z      8-11V/5.62-4.09A/45W           90

AGM050-S12-z      11-13V/4.54-3.84A/50W        100

AGM050-S15-z      13-16V/3.84-3.12A/50W        100

AGM050-S18-z      16-21V/3.12-2.38A/50W        150

AGM050-S24-z      21-27V/2.38-1.85A/50W        150

AGM050-S27-z      27-33V/1.85-1.51A/50W         200

AGM050-S48-z      33-58V/1.51-1.04A/50W         200

z: C6/C14 inlet        Mechanical Drawing  Attached: AGM050 desktop mechanical                             Load Regulation: +/-5% Max.

Line Regulation: +/-1% Max.  

Insulation resistance: 50Mohm min. from Input to output                    

Over Current: All output protected to short circuit conditions

Over Voltage Protection: Provided on outputs set at 112-132% of its nominal output voltage

Over temperature Protection: 130°C Activated

Setup/Hold up/ Rise time: Typ.: 1000mS/10mS/50mS at full load

Derating : Derated from 100% at +40°C linearly to 50% at +70°C

Temperature Coefficient: All output +/-0.04% / °C max.

Withstand Voltage: 5656VDC from input to output

Operating Temperature: 0~40degree C

Storage Temperature: -40~85degree C

Storage Humidity: 5~95% RH

Transient Response: Max. Excursion of 4% better on all models. Recovering to 1% of final value within

                 500uS. after a 25% step load change

EMC:  EN600601-1-2: 2007, FCC Part 15 & Part 18 class B

Safety: UL60601-1: 2005, CSA: C22.2 60601-1: 2008, EN60601-1:2006
Spec Attached: AGM050 desktop.docx


Subscribe to Latest NewsSubscribe to Latest News Subscribe to Merchandise NewsSubscribe to Merchandise News The copyright of this website belongs to Astek Globe.