Products
Astek catch your demand on Power Supply Astek catch Your Demand on Power Supplies google-site-verification: googlec41a4fffdccfe80c.html '
Home Medical Adapter AGM030 30W Medical Desktop Power Adapter

AGM030 30W Medical Desktop Power Adapter

*Input 100~240VAC *Output 5V~58V*DOE VI/CoC 5*Protection:Overcurrent/Overvoltage/Short Circuit *Means of Patient Protection Design*Possess risk analysis report*UL,cUL60601, EN/IEC60601 3rd edition *Two years warranty

AGM030  30W Medical Desktop Adapter

 

*Universal AC Input Range

*DOE VI/CoC 5

*Protections: Overcurrent/ Overvoltage/Short Circuit

*Means of Patient Protection Design

*Possess risk analysis report

* UL, cUL60601, EN/IEC60601 with 3rd Edition and CE, FCC approved.

*Warranty two Years

*Application: Medical power, Medical charger(CV mode), Power Supply for Health care

Input Voltage: 90~264VAC

Frequency: 50~60Hz

Input current: 1A max.   

Leakage Current: 0.1mA max. @240VAC /50Hz                          

Inrush current: 50A @115VAC; 90A @230VAC at 25°C cold start  

Part No          Rated O/P(current max.)        Ripple & Noise(mV p-p)

AGM030-S05-z      5-6V/4-3.33A/20W                   150

AGM030-S75-z      6-8V/4.17-3.13A/25W                150

AGM030-S09-z      8-11V/3.75-2.73A/30W               100

AGM030-S12-z      11-13V/2.73-2.3A/30W               100

AGM030-S15-z      13-16V/2.3-1.88A/30W               100

AGM030-S18-z      16-21V/1.88-1.43A/30W              100

AGM030-S24-z      21-27V/1.43-1.11A/30W              100

AGM030-S27-z      27-33V/1.11-0.9A/30W              100

AGM030-S48-z      33-58V/0.9-0.51A/30W              100

 z: C6/C14/C8 inlet    weight: Appro. 180-200g  medical Attached: AGM030 desktop mechanical          

Load Regulation: +/-5% Max.

Line Regulation: +/-1% Max.  

Insulation resistance: 50Mohm min. from Input to output                    

Over Current Hiccup mode; auto-recovery, rate output current >110%

Over Voltage Protection: Protected by Zerner diode, Rated output voltage 110~140%

Short circuit Protection: auto recovery

Setup/Hold up/ Rise time: Typ.: 1000mS/10mS/50mS at full load

Efficiency: DOE VI

Derating: Derated from 100% at +40°C linearly to 50% at +70°C

Temperature Coefficient: All output +/-0.04% / °C max.

Withstand Voltage: 5656VDC from input to output

Operating Temperature: 0~40degree C

Storage Temperature: -40~85degree C

Storage Humidity: 5~95% RH

Transient Response: Max. Excursion of 4% better on all models. Recovering to 1% of final value within 500uS. after a 25% step load change

EMC:  EN600601-1-2: 2007, FCC Part 15 & Part 18 class B

Safety: UL60601-1: 2005, CSA: C22.2 60601-1: 2008, EN60601-1:2006

Spec Attached: Attached: AGM030 desktop.docx